显示标签为“FLS of Cameron Gate Valve difference”的博文。显示所有博文
显示标签为“FLS of Cameron Gate Valve difference”的博文。显示所有博文

2016年3月11日星期五

What is the difference among Model FC,FL,FLS of Cameron Gate Valve?

Jining Donghong Machinery Co., Ltd
China Oilfield equipment and spare parts supplier
Dedicate to Petroleum E&P Business,Strive to Be a World-class Service Provider


Contact us
SKYPE:spareparts1960
Mobile/WhatsApp:0086-189-5407-9939

What is the difference among Model FC,FL,FLS of Cameron Gate Valve?

Cameron FC Gate Valve consists of 6 sealing surfaces:
Body to Body Bushing (x2)
Body Bushing to Seat Ring (x2)
Seat Ring to Gate (x2)

Cameron FLS Gate Valve consists of 4 sealing surfaces:
Body to Seat (x2)
Seat to Gate (x2)

Cameron FL Gate Valve has a single-pressure,energized peek lip seal in the seat to body interface.

Cameron FLS Gate Valve employs two lip seals.

If you have more advice,welcome to leave message.