What is the difference among Model FC,FL,FLS of Cameron Gate Valve?

Jining Donghong Machinery Co., Ltd
China Oilfield equipment and spare parts supplier
Dedicate to Petroleum E&P Business,Strive to Be a World-class Service Provider


Contact us
SKYPE:spareparts1960
Mobile/WhatsApp:0086-189-5407-9939

What is the difference among Model FC,FL,FLS of Cameron Gate Valve?

Cameron FC Gate Valve consists of 6 sealing surfaces:
Body to Body Bushing (x2)
Body Bushing to Seat Ring (x2)
Seat Ring to Gate (x2)

Cameron FLS Gate Valve consists of 4 sealing surfaces:
Body to Seat (x2)
Seat to Gate (x2)

Cameron FL Gate Valve has a single-pressure,energized peek lip seal in the seat to body interface.

Cameron FLS Gate Valve employs two lip seals.